See every rack,
every watt,
every connection.
The cloud-native DCIM platform that maps your entire physical infrastructure—power, space, network—in one system of record. Built on a power model that tracks capacity three ways, so you can see the 15–35% of your facility you have already paid for but cannot use.
Or run Community Edition free — Docker Compose, your infrastructure, no sales call.
DC1 · Hall B · 1.2 MW
Stranded: 322 kW provisioned but not drawing — $58K/mo at your rate.
Illustrative figures
Every tool says “used.” Your facility means three different things by it.
Rackvio stores all three as separate quantities at every node of the power chain, from utility feed to outlet, and computes the gaps between them continuously.
Promised to someone
under contract, or allocated to a project
Gone the moment it is signed, whether or not a single server is racked. Treat it as available and you promise the same kilowatt twice.
Assigned to equipment
nameplate of what is installed
What the design expects the gear to draw. It stays locked at the nameplate figure long after the hardware proves it never gets close.
Actually drawing
measured at the outlet
What the utility bill, the cooling load, and the failover math run on. Typically 35–55% of the nameplate figure above it.
Collapse these into one number and the gaps disappear — and the gaps are where the capacity is.
From spreadsheet chaos to total clarity
Stop tracking racks, power, and IPs in spreadsheets that go stale the moment you save them. Rackvio gives you a single, live system of record.
| A | B | C | D | E | |
|---|---|---|---|---|---|
| 1 | Rack-A04 | 192.168.1.? | 4.2 kW | Room 3 | ??? |
| 2 | Rack-B12 | 10.0.0.15 | OUTDATED | Room 1 | 2U Server |
| 3 | ??? | 172.16.0.1 | 3.8 kW | ??? | PDU |
| 4 | Rack-C07 | N/A | ??? | Room 2 | MISSING |
| 5 | Rack-A04 | 192.168.1.50 | 5.1 kW | DUPLICATE | Switch |
Stale data, broken references, no single source of truth
Live floor plans, real-time power data, one system of record
Everything you need to manage physical infrastructure
Seven core modules that replace spreadsheets, Visio diagrams, and tribal knowledge with a single, always-accurate system of record.
Track every watt from utility feed to outlet. A three-state capacity model surfaces stranded power so you stop paying for capacity you cannot use.
Drag-and-drop room layouts with rack placement and live capacity overlays. See exactly where space is available before you commit.
Procedurally rendered SVG faceplates for every device, every U-position, front and rear. Always accurate, never out of date.
Hierarchical prefix management with automatic address allocation and conflict detection. No more spreadsheets, no more collisions.
A shared catalog of device types with faceplate specs, power profiles, and port templates. Define once, deploy everywhere.
Row-level security with tenant-scoped views and role-based access control. Every customer sees only their data, guaranteed.
EU EED Article 12, CSRD ESRS E1, per-tenant Scope 2, and 24/7 CFE reporting as auditable exports and API. Built for the regulatory calendar.
The arithmetic, and where it comes from
Four numbers, each traceable to the three-state capacity whitepaper — including a two-CSV calculation you can run against your own exports before you talk to us.
35–55%
Steady-state draw as a share of nameplate. Provisioned capacity stays locked to the nameplate figure; the difference is stranded.
of nameplate
30–50%
The provisioned-to-consumed gap across a typical hall.
provisioned vs consumed
15–35%
Facility capacity recoverable without construction, new switchgear, or a site walk.
of total facility
$270–840K
Per stranded megawatt, per year — recovered revenue at colocation wholesale rates, or deferred capex if you run your own floor.
per stranded MW / yr
Patent-pending innovation
Built on novel approaches to data center intelligence that do not exist in any other platform.
Identifies stranded capacity across your entire power distribution tree, from utility feed to individual outlets. See every watt you are paying for but not using.
Generates pixel-accurate equipment visuals from specification data alone. No manual drawing, no image libraries — every faceplate is computed on the fly.
Reserve power, space, and network capacity before physical deployment. Plan months ahead with guaranteed resource allocation.
Start your free trial
Spin up Rackvio in minutes — a 30-day Cloud Growth trial. Card required, cancel anytime before day 30.