Rackvio

See every rack,
every watt,
every connection.

The cloud-native DCIM platform that maps your entire physical infrastructure—power, space, network—in one system of record. Built on a power model that tracks capacity three ways, so you can see the 15–35% of your facility you have already paid for but cannot use.

Or run Community Edition free — Docker Compose, your infrastructure, no sales call.

DC1 · Hall B · 1.2 MW

Committed840 kW
Provisioned to equipment610 kW
Consumed at the outlet288 kW

Stranded: 322 kW provisioned but not drawing — $58K/mo at your rate.

Illustrative figures

Patent-Pending
Cloud-Native
API-First

Every tool says “used.” Your facility means three different things by it.

Rackvio stores all three as separate quantities at every node of the power chain, from utility feed to outlet, and computes the gaps between them continuously.

Committed

Promised to someone

under contract, or allocated to a project

Gone the moment it is signed, whether or not a single server is racked. Treat it as available and you promise the same kilowatt twice.

Provisioned

Assigned to equipment

nameplate of what is installed

What the design expects the gear to draw. It stays locked at the nameplate figure long after the hardware proves it never gets close.

Consumed

Actually drawing

measured at the outlet

What the utility bill, the cooling load, and the failover math run on. Typically 35–55% of the nameplate figure above it.

Collapse these into one number and the gaps disappear — and the gaps are where the capacity is.

From spreadsheet chaos to total clarity

Stop tracking racks, power, and IPs in spreadsheets that go stale the moment you save them. Rackvio gives you a single, live system of record.

The Old Way
fx=VLOOKUP("Rack-A04",Sheet2!A:E,3,FALSE) — #REF!
 ABCDE
1Rack-A04192.168.1.?4.2 kWRoom 3???
2Rack-B1210.0.0.15OUTDATEDRoom 12U Server
3???172.16.0.13.8 kW???PDU
4Rack-C07N/A???Room 2MISSING
5Rack-A04192.168.1.505.1 kWDUPLICATESwitch
Racks_2024Power_OLDIPs_BROKEN

Stale data, broken references, no single source of truth

The Rackvio Way
Room 3 — Hot Aisle
Live
R3
R3-A04
R10
12 Racks48.6 kWAll healthy

Live floor plans, real-time power data, one system of record

Everything you need to manage physical infrastructure

Seven core modules that replace spreadsheets, Visio diagrams, and tribal knowledge with a single, always-accurate system of record.

The arithmetic, and where it comes from

Four numbers, each traceable to the three-state capacity whitepaper — including a two-CSV calculation you can run against your own exports before you talk to us.

35–55%

Steady-state draw as a share of nameplate. Provisioned capacity stays locked to the nameplate figure; the difference is stranded.

of nameplate

30–50%

The provisioned-to-consumed gap across a typical hall.

provisioned vs consumed

15–35%

Facility capacity recoverable without construction, new switchgear, or a site walk.

of total facility

$270–840K

Per stranded megawatt, per year — recovered revenue at colocation wholesale rates, or deferred capex if you run your own floor.

per stranded MW / yr

Patent-pending innovation

Built on novel approaches to data center intelligence that do not exist in any other platform.

Patent-Pending
Power Gap Analytics

Identifies stranded capacity across your entire power distribution tree, from utility feed to individual outlets. See every watt you are paying for but not using.

Patent-Pending
Procedural Faceplate Rendering

Generates pixel-accurate equipment visuals from specification data alone. No manual drawing, no image libraries — every faceplate is computed on the fly.

Cloud Growth+
Patent-Pending
Capacity Reservation

Reserve power, space, and network capacity before physical deployment. Plan months ahead with guaranteed resource allocation.

Start your free trial

Spin up Rackvio in minutes — a 30-day Cloud Growth trial. Card required, cancel anytime before day 30.